Phase 0: Digital Spheromak Relaxation Achieved
The non-linear 3D magnetohydrodynamic 1,000-step solver sequence in ElmerFEM
(WhitneyAVSolver) has successfully converged into a force-free Taylor state.
SOLVER FINISHED: 2026/06/14 (13-Day Compute Run on 32-Core MPI Cluster)
By enforcing a conductive flux-conserving boundary condition (\(\mathbf{B} \cdot \hat{\mathbf{n}} = 0\)),
magnetic helicity (\(H^M = \int \mathbf{A} \cdot \mathbf{B} \, dV\)) was prevented from bleeding off.
Unlike earlier un-conserved runs that collapsed into vertical Z-pinches, the confined plasma relaxed into
a self-organized toroidal state.
Because an insulating polycarbonate wall cannot act as a magnetic flux conserver on its own, physical translation now utilizes a Slotted Thin-Shell C110 Copper Flux Conserver (\(0.35\text{ mm}\)) mounted inside our 500mm 1-Atmosphere Cold Phantom Calibration Rig, paired with an STM32G484VEH6 active saddle-coil feedback loop.
1. Pulsed-Power RLC Discharge Simulator (Upgraded)
Interactive RLC matrix with realistic microhenry (\(\mu\text{H}\)) coil inductance and loop resistance for sizing both our Stage 1 Benchtop Calibration Driver and Stage 2 Pulsed Formation Bank.
2. Slotted Copper Flux-Conserver & Skin-Depth Calculator
Calculate the exact Stage 1 trade-off between passive \(n=1\) tilt braking time (\(\tau_{\text{wall}}\)) and external STM32G484 saddle-coil field penetration across a slotted \(R = 250\text{ mm}\) copper shell. (For full 3D interactive visualization, open the 3D Stage 1 Studio).
Simulation Archives (Unbounded Stress Tests)
Historical telemetry of early non-linear MHD solver runs without a conductive flux-conserving wall, demonstrating why an un-conserved boundary collapses into a Z-pinch regardless of drive current.
1,000 Step: 500A Seed / 100kA Main Pulse — FAILED (Un-Conserved Z-Pinch)
2D Cross-Sectional Line Render of the Project Elyasia plasma ignition sequence, mapping the magnitude of
the magnetic flux density. This run tests a two-stage current injection designed to trigger a relaxed
Taylor State.
The visualization shows the faint blue outline of the initial 500 Amp seed field (\(0\text{–}200\text{ ns}\)),
which establishes a pre-ionized conductive channel. When the main capacitor discharge engages without a
conductive boundary wall (flux conserver) to provide counter-magnetic image-current pressure against the
expanding plasma, the geometry fails to relax into a Spheromak, collapsing instead into a Z-pinch along
the vertical axis.
800 Step: 100kA Single-Stage Pulse — FAILED (Boundary Loss)
Diagnostic confirmation of boundary state failure. Reducing the numerical drive by two orders of magnitude yielded the exact same geometric collapse as the unbounded \(20\text{ MA}\) numerical stress test. This proved the solver was suffering a boundary flux-loss failure rather than a simple over-current instability, motivating both the two-stage pre-ionization seed and the conductive flux conserver.
300 Step & 60 Step: Unbounded 20 MA Numerical Stress Test — FAILED
Initial numerical scaling test visualizing the Alfvénic instability cascade when an extreme unscaled current source impacts un-preionized gas without wall stabilization. The radial Lorentz forces shredded the toroidal mesh before poloidal reconnection could occur.